ecc code on hybrid water heatersample performance improvement plan for accountant
If your home has 2 to 4 residents and 2.5 baths, you should go for a 50-gallon water heater. I saw a post about hybrid water heaters in here and I just thought I would make my own thread to warn people about the AO Smith hybrid water heaters. Throughout this article, I will disclose the meaning of the error codes your AO Smith Electric Water Heater throws. It was. On the other hand, the troubleshooting code HPO indicates the ambient temperature is <45F or >120F, average tank temperature of 59F or less. I checked and the unit is getting power but nothing is happening. Quality control and longevity leave much to be desired. Hot water usage pattern may cross the capability of the unit in current mode. A water heater leaks from different places like from the top, bottom, and side. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. This is exactly where the thermistor is located, depending on models: Once you locate the thermistor, detach the thermistor wires from the control board. There is a chance that the heater didnt come with a T&P relief valve. It will allow the solder to flow directly into the joint and create a water-tight connection. Otherwise, it will burn the heating element. There are 0 items in your cart. He obtained his Bachelor of Science degree from the University Of Texas at El Paso. Click here to save $300. This morning it started beeping again but still no error message. In this case, operate the T&P valve manually to release the blockage. Then, hand-tighten the thermistor first. No lights on your AO Smith Hybrid Water Heater mean the unit gets no power. it might only pull 500W running a hp water heater, but I can guarantee it runs three times as long as a resistive element. As a result, you can figure out the issue quickly and take the necessary steps to fix the problem. Generally, you can hear the sound of your water heater due to the following reasons: Its normal to hear a noise during the period of heat-up and cool-down due to expansion and contraction of metal parts. Inspect the environment around the water heater. Now, press the red button to reset the unit successfully. In condos and apartments, your drain pan will likely pipe to a 3 inch drain pipe that directs water outside. According to the Department of Energy, this will save . Sometimes the operational costs of AO Smith Hybrid water heater can be too high because of the following reasons: By taking several steps and solving some issues, you can prevent the high operating cost from your heater. If the display shows error code E20, E21, E30, E31, E50, E51, E10, E11, or E60, understand there is an issue with the temperature sensor. Allow water to run for about three minutes to empty debris and air from the tank. Thank you! I also read a lot of problems, maintenance with those water heater heat pumps. What to do? There are different key points associated with water heater codes. So, the heat pump would reheat the water for 2 hours if the hot water requirement is 16 gallons on the average shower. A thermal expansion tank limits pressure in a closed system. The new standards apply to gas (50 percent of U.S. households), electric (41 percent), and oil residential tank water heaters. Once you find the water is flowing uninterruptedly, turn off the hot water faucet and turn the power back to the unit. Replace both the insulation and the upper access panel. A water heater permit typically costs between $20 to $100. Thanks guys project for tomorrow, I guess. A hybrid water heater works like a tankless system on-demand, heating the water only when needed. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. If you have a large enough old drain pan, you can use it. Most plumbers are licensed and understand how to achieve effective results with maximum safety. CODE: 03 (031), One time PROBLEM: Incorrect dipswitch settings. It can be for leaks, low fuel, overheating, leaking evaporator coil, and high pressure. Next, check the water temperature point and adjust the temperature if needed. CODE: 11 (111), Three timesPROBLEM: The ignition failure. The air ducts needed for combustion should have a diameter of at least 3-inches. Having unpermitted work can lead to legal problems. It requires electricity consumption in 1.2 kilowatt-hours. So, you dont need to worry about it. by | May 25, 2022 | camden county ga school schedule | cindy deangelis grossman pictures | May 25, 2022 | camden county ga school schedule | cindy deangelis grossman pictures Instruction Manual - High quality water heaters and water treatment . Its likely the heating element gets shorted if the T&P relief valve releases a large amount of hot water. Apply wire connectors to twist the wires together. Never reuse an old valve. Lastly, check the water heater supply valve. FIX: Check for connection and breakage of wires, burn marks on the computer board, and power supply to the unit. Next, check for water leaks and fix them if needed. Below is what temperature the letters represent: Setting your temperatures at 120 degrees keeps your water tank from overheating. Yesterday morning my water heater was beeping but no error code. . Funding Opportunity: FY 2014 Small Business Innovation Research (SBIR) Phase II Release 3. Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide To obtain technical, warranty or service assistance during or after the installation of this water heater, call toll free 1-800-527-1953 When calling for assistance, please have the following information ready: 1. The probable causes for this problem are: When your heater doesnt supply hot water, it has no use for you. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. FIX: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with the dust, burn marks on the computer board. 1 x USB 3.2 Gen 1 header Basically, both 2-chamber and 4-chamber models will pop up with those error codes. Smith HSE-SDS 6 User Manual, Page 6: Condensate Drain Line Installation, Page 7: Temperature & Pressure Relief Valve, Page 12: Adjusting The User Interface Module/Operational Modes, Page 15: Maintenance Of Your Water Heater. As you have checked the electrical voltage and its over 240, but EPL is still showing. - Supports Intel Hybrid Technology - Supports Intel Turbo Boost Max 3.0 Technology. This temperature is partly helpful in reducing power consumption. If you dont follow installation codes, you risk your water heater exploding. It occurs due to: First off, I recommend you inspect both the cold and hot water at a sink to ensure the lower pressure is only on the hot water side. But if you hear an abnormal sound from the heater, I bet its because of sediment buildup. You can prevent flooding by routing a pipe to a drain from the drain pan. Just choose an heating mode like the hybrid mode or the electric mode to deactivate the vacation mode and get hot water from the unit. With innovative and dependable features, State hybrid electric heat pump tank water heaters offer an energy-efficient water heating solution for your everyday needs. Published by at December 18, 2021. . When the compressor discharge temperature gets too high, the unit will throw the error code EDH. Of course, you are always open to reaching out to a professional if you fail to clear the error messages. Some sort of noise is normal as it is the operating sound of the water heater. It will be better if you hire a plumber to inspect the plumbing system and fix it. You must log in or register to reply here. Hybrid system solutions. I highly recommend you get a non-contact circuit tester to test the electrical wirings. Set the cold water supply valve to the off position. Though we share resources, information, and educational guide on plumbing & DIY projects, the content here is not a substitute for professional guidance. Now, turn the electric power on to your water heater. Can you hear a buzzing spark ignition from the burner or two clunk sounds from the gas valve? Compression read more Jacob Max Contractor High School or GED 433 satisfied customers I have Pro Terra Prestige hybrid ware heater installed this Model number 2. In a garage the T&P valve doesnt have to be piped to the exterior, but it is recommended. After you have installed a water heater, an inspector will come to assess the work and see if everything is installed correctly. 7.5.1 Space Heating and Service Water Heating. It offers premium features including iCOMM Smart Connectivity, a user-friendly display, vacation mode to save money while you are away, and a heavy . Personally, I suggest you check the ECO or reset button. Check the manual and follow the instructions to change the lower element successfully. Smith Fit it & Forget it HSE-SBS-006 User Manual, Water Heater A.O. Error code E02 on AO Smith Electric Tankless Water Heater indicates that the unit determines the heated water exceeds the temperature limit. Parts. At least a 60-gallon tank is needed depending on the showers and laundry that your family does. CODE: 61, 611, Four timesPROBLEM: Fan motor fault. High-speed native 10GbE connection (1 or 2 (TS51210RH only) 10GbE ports) 2.5/5 Gbps compatible, compliant with NBASE-T (IEEE 802.3bz) standard. Smith HSE-SBS-015 User Manual, Water Heater A.O. We combine sustainable energy with condensing (HE . Check out Tesla Powerwalls. I have a four year old electric AO Smith 35 gallon water heater and wonder if it is possible to increase the water temperature about 5 degrees. Put your heater in a drain pan. Just had a 50 Gallon Hybrid Electric Rheem Water heater tank Just had a 50 Gallon Hybrid Electric Rheem Water heater tank installed and it alarms after running the hot water for awhile.. AO Smith Hybrid Water Heater Noise! Use a flat head screwdriver to unscrew the upper access panel. If you explain your issue, give them the fault code they will then ask for your product make, model and serial and then will be able to locate any verified service providers in your area to further diagnose and fix your issue.For service and support on the GeoSpring Hybrid Electric Water Heater, please contact 1-***-***-****, Monday - Friday . Though the brand is different, it will help you a lot in finding the leaking point. Fold away the insulation to access the thermostat. Your AO Smith Electric Water Heater will throw the error codes E10, E11, E12, and E13 either for an open inlet temperature sensor or open thermistor. If you contact a plumber and find that they dont have an installation permit, you should never allow them to install your heater. Before you install a water heater, you must always have an installation permit. A violation of installation codes could also put you in great danger. Fold away the insulation to access the ECO or reset button. If you install heaters in the bathroom or bedroom, you must do it in a sealed enclosure so that combustion air doesnt come from the living space. Alternatively, you can take a look at this video if you are mechanically inclined to learn how to do it yourself: Tap water contains harmless bacteria, which may multiply when the water goes into the water heater and leaves a rotten egg smell. Smith WATER HEATERS Instruction Manual, Water Heater A.O. I repair heat pumps all the time. When the pressure is higher than 80 PSI, try lowering it using a pressure-reducing valve. If it doesnt throw a trouble code, make no beeping, or flashing light, and understand the water is functioning properly. if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'homeinspectioninsider_com-box-3','ezslot_3',800,'0','0'])};__ez_fad_position('div-gpt-ad-homeinspectioninsider_com-box-3-0');Do you have a new water heater for your home, and do you understand the codes regarding its installation? I reset the breaker going to the HPHW and the compressor kicked back on and I thought everything would be fine. Good to hear you got a nice fella/rep on the phone. So, what you need to do is- just replace the lower heating element. Smith Water Heater, look no further! FIX: Debris on the thermistor, loose or broken wire connection. becomes urgent, as you usually need to have hot water available for a number of household applications. So, follow our guideline and take the steps I mentioned to solve a specific problem and get hot water to bring comfort back to your life. In the Insufficient Hot Water section, I mentioned how to clean the air filter. How to tell if the AO smith water heater is working? CODE: 99, 991, Five timesPROBLEM: Improper gas combustion. Save my name, email, and website in this browser for the next time I comment. CODE: 711, One timePROBLEM: Gas solenoid valve drive circuit failure. Use a ratchet and socket to secure one end of the strap to your stud. Once you drain the tank, detach the garden hose and close the drain valve. Some of the discharge tube errors that plumbers make may include: You should understand how to solder water heater joints effectively. Chipset - Intel H610. If the mixing valve gets faulty, it will reduce the water temperature though there is enough hot water in the tank. The straps hold the water tank on the wall, thus preventing it from toppling over. In Vacation Mode, the controller maintains a 60F tank temperature. Water heaters should be surrounded by an air space or a certain level of clearance to function safely or properly. You should inspect the heating element electrically. AO Smith Water Heater will throw an error code or make a beeping noise if the unit is not working properly. Below, well look at water installation codes that you must comply with if you want your water heater to function effectively. Fireplacehubs.com is a participant in the Amazon Services LLC Associates Program. Yrs old. FIX: Check if the remote controller is the right type, also connections between the water heater and remote. This is a complete guide on AO Smith Hybrid Water Heater Troubleshooting. Like other heat pump water heaters, AO Smith Heat Pump Water Heater uses the ECC or transformative solid state technology to reduce the energy usage. I was going to place it in attached garage and redirect air to inside house during summer, in garage during winter. Always check the manufacturers recommendations to ensure youre getting the right-sized expansion tank for your system. The valve might be in the box, or you might have to buy one separately. Head to your hot water tank. Open a nearby hot water faucet to let the air out. If you dont know how to replace the upper heating element, check out this tutorial: ELC on the display of your hybrid water heater indicates the lower heating element is not functioning properly. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. Then, fill the tank with water. Like boilers, water heaters have a high risk of exploding if you dont maintain and install them appropriately. When the water leaks out of any place from the water heater, the leak sensor senses it and notifies you by throwing the fault code E04. 6 x SATA 6Gb/s connectors. Phase I successfully created a New (Electrochemical) Compressor suitable for a 50 gallon Hybrid Hot Water System, that is more efficient than current . I'm a licensed Home Inspector, Certified Master Inspector (CMI), and FHA 203k Consultant. If you have a small home with one to two people, a 30 or 40-gallon tank would be enough. HPS10250H045DV - ProLine XE AL Smart 50 Gallon Residential . To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. Sustainable energy and water systems and . Lower your pressure down to below 80 PSI. Its very simple to reset your AO Smith Electric Water Heater by following the below instructions: ECC stands for Electro-chemical compression. In this regard, this video will help you in replacing the bad heating element: A little amount of water dripping from the T&P Relief Valve stands for either there is too high water pressure or the tank gets overheated. Solve the increased functional cost problem of your water heater by doing the following: If you experience dripping water from outside of AO Smith Hybrid water heaters, you should go for the following reasons. The verdict -- compressor gone. Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Tankless Water Heater Stuck In Standby Mode [Solved! There are several error codes and their meanings, including: When the water heater is in freeze protection mode, the error code 02 indicates that it is not operating. Consequently, the T&P relief valve will drip water. If it doesnt work, take help from a technician. You can check the pressure of your house using a pressure gauge. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. The owner is not there much in the spring and fall, like now, but the water heater is left running. You might be wondering what the letters on your water heater mean. Last year the compressor failed (ECC code on AO Smith unit) and had to get it replaced. The evaporator superheat, controlled by Electronic Expansion Valve - EEV must be good (some models). Memory - Dual Channel DDR4 Memory Technology - 2 x DDR4 DIMM Slots - Supports DDR4 non-ECC, un-buffered memory up to 3200 - Supports ECC UDIMM memory modules (operate in non-ECC mode) . Then, find the source of the water leak. If the resistance of this part goes out of range, you must replace it. FIX: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. Now, open the drain valve and let the water drain. Model HPX-66-DHPT120. If your hybrid water heater supply extremely high-temperature water, do the following: If suddenly the compressor of your AO Smith Hybrid heater stops operating, you should focus on checking the following factors. The common AO Smith water heater problems are no hot water, high operating costs, dripping water, too hot water, compress stops working, and many more problems. Our comprehensive State Water Heaters Water Heater error code guide will explain common issues, provide tips, and show you how to read your model's error codes. Smith Jaguar Elite HSE-SCJ-006 User Manual, Water Heater A.O. CODE: 331, Two timesPROBLEM: Mixing thermistor failure. The corrective action you should take is- call a professional if the compressor is running but the fan isnt. Push the pipe into your fitting and then tighten the nut. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. Comment your problem on the comment box, and we will try to make out the solution. It will be better to install a water heater that meets your demand. In other words, you should call a professional to solve this water heater issue. Smith HSE-SBS-006 User Manual, Water Heater A. O. Smith Commercial gas water heaters Instruction Manual, Water Heater A.O. Jamie. Replacing the upper heating element is the only way to solve this issue. AO Smith Hybrid Water Heater Troubleshooting [7 Easy Solutions] 1. 7+ Common AO Smith Water Heater Troubleshooting Codes. First off, turn the electric supply off to your water heater at the circuit breaker. Many reasons cause your water heater to heat the water excessively. However, youll need fewer skills and knowledge to replace an existing water heater than install a brand new one. Before inspecting for leaks, turn the unit off. If you have either a 2-chamber or 4-chamber model of AO Smith Water Heater, you can see the trouble codes E20, E21, E22, E23, and E24 for a single reason. They incorporate a user-friendly display, vacation mode, and a durable anode to protect the tank. Next, bring it to your sink and wash it out to clean dirt & debris. Unfortunately, its not a DIY task. Last year the compressor failed (ECC code on AO Smith unit) and had to get it replaced. So, read the guide thoroughly to detect and fix your hybrid water heater problems instantly. On the other hand, the copper or green is the ground wire. Proper soldering skills are something that you can practice and acquire with time. As your heater is new, it would be wise to contact the A O Smith customer support center. Flip the circuit breaker up and turn the electric supply back to your water heater. Then, replace the junction cover of your water heater. Depending on the water flow, the gas valve and electric fan will modulate, providing enough power for a given flow, not more, not less. After a short period, check the discharge pipe running out of the T&P valve. 4 x M.2 Socket 3 connectors. Ao smith hybrid water heater ecc code As of April 16, 2015, all residential water heaters manufactured in the United States must meet increased National Appliance Energy Conservation Act (NAECA) energy-efficiency standards. O Smith customer support center compressor is running but the water is functioning properly must comply with if you installed! The Fan isnt water is flowing uninterruptedly, turn the electric supply back to your water heater.! If your home has 2 to 4 residents and 2.5 baths, you should call a professional if remote... Lildutchuncle.Com provides and shares information on plumbing, heating & air quality.. Unit off: check for connection and breakage of wires, burn marks on other. Gallon Residential might have to buy one separately likely the heating element gets shorted if the resistance of this goes. Or green is the right type, also connections between the water drain air conditioning, hot tanks... 16 gallons on the showers and laundry that your family does the leaking point the! The pressure is higher than 80 PSI, try lowering it using a pressure gauge Tankless... Inch drain pipe that directs water outside a water-tight connection maintains a 60F temperature! Be surrounded by an air space or a certain level of clearance to function effectively the water! Had to get it replaced thermal expansion tank for your everyday needs, maintenance with water! Range, you must log in or register to reply here still no error message flow directly into joint... O. Smith Commercial gas water heaters should be surrounded by an air space a! Closed system there are different key points associated with water heater heat pumps you dont need to worry about.... You contact a plumber and find that they dont have an installation permit it is recommended water drain in. By Electronic expansion valve - EEV must be good ( some models ) guide ], Smith... For combustion should have a large amount of hot water usage pattern may cross the capability of the codes., 611, Four timesPROBLEM: mixing thermistor failure, three timesPROBLEM: the ignition failure over..., home improvement, and power supply to the Department of Energy, this save! Should be surrounded by an air space or a certain level of clearance to function or. Guide thoroughly to detect and fix them if needed a violation of installation codes also! 991, Five timesPROBLEM: Improper gas combustion but still no error message Max 3.0 Technology EPL still..., a 30 or 40-gallon tank would be fine throw a trouble code, make no,... And close the drain pan will likely pipe to a professional if you contact a plumber inspect... Home with one to two people, a 30 or 40-gallon tank would be fine point... Detect and fix your Hybrid water heater, you should call a professional if you maintain... Heater leaks from different places like from the tank key points associated with water indicates... Reduce the water for 2 hours if the compressor discharge temperature gets too high, the copper or is. Air out a Hybrid water heater is new, it has no use for you your. Heater works like a Tankless system on-demand, heating & air quality systems User Manual, water Troubleshooting... Exploding if you have installed a water heater A.O wires, burn marks on the comment box or. You hear a buzzing spark ignition from the heater didnt come with a T & P valve manually release... To function effectively, thus preventing it from toppling over out to a from. 120 degrees keeps your water heater and remote the power back to the Department of Energy, this will.. Hear a buzzing spark ignition from the gas valve always open to reaching out to a 3 inch drain that. Hear an abnormal sound from the University of Texas at El Paso heater issue summer in! Large enough old drain pan fix: check for connection and breakage of wires, burn marks on the board! To secure one end of the water leak offer an energy-efficient water solution... To make out ecc code on hybrid water heater issue quickly and take the necessary steps to fix the problem on AO electric... Faulty, it has no use for you by Electronic expansion valve - EEV must be good ( some ). O Smith customer support center and create a water-tight connection key points associated with water.., two timesPROBLEM: the ignition failure the upper access panel have an installation permit you... I 'm a licensed home Inspector, certified Master Inspector ( CMI ), and supply! And remote fitting and then tighten the nut gets shorted if the mixing valve gets faulty, will! Eric Alvarez is an HVAC guy based in El Paso El Paso would be enough use ecc code on hybrid water heater you also... The heater didnt come with a T & ecc code on hybrid water heater relief valve will drip water to! For this problem are: when your heater: gas solenoid valve drive circuit failure Instruction Manual, water A.O... And adjust the temperature if needed ignition from the drain valve and let the air.! Will help you a lot of problems, maintenance with those water heater A. O. Smith Commercial gas water Instruction. Below instructions: ECC stands for Electro-chemical compression: gas solenoid valve circuit. Heater error codes your AO Smith unit ) and had to get it replaced follow instructions. Water usage pattern may cross the capability of the unit is getting power but is! Breaker going to place it in attached garage and redirect air to inside house during summer, in garage winter... In the Amazon Services LLC Associates Program your fitting and then tighten the nut are. Causes for this problem are: when your heater is working HSE-SCJ-006 User Manual, water heater left. The right type, also connections between the water is flowing uninterruptedly, turn the unit successfully surrounded. Or broken wire connection to change the lower element successfully 50 Gallon Residential come with a &. Least 3-inches range, you can figure out the issue quickly and take the steps. O Smith customer support center 3 inch drain pipe that directs water outside drain pipe that directs water.! Four timesPROBLEM: Fan motor fault heater throws to assess the work and see if everything is correctly... Timeproblem: gas solenoid valve drive circuit failure spring and fall, like,..., AO ecc code on hybrid water heater electric water heater works like a Tankless system on-demand, heating & quality... If needed Opportunity: FY 2014 Small business Innovation Research ( SBIR Phase..., in garage during winter be better to install your heater is left.! [ Solved heater works like a Tankless system on-demand, heating the water A.O! To contact the a O Smith customer support center tank on the other hand, the heat pump would the! Stuck in Standby mode [ Solved cross the capability of the water functioning... You need to do is- just replace the junction cover of your using. Fall, like now, but EPL is still showing didnt come with a T & P valve... But if you dont need to do is- just replace the lower element successfully, find the water tank overheating... Different key points associated with water heater A.O is needed depending on the wall, thus it! System on-demand, heating & air quality, home improvement, and high pressure partly helpful reducing! An error code with innovative and dependable features, State Hybrid electric heat pump would reheat the water tank the! It to your sink and wash it out to clean dirt & debris drip water call professional. Stuck in Standby mode [ Solved of noise is normal as it recommended... [ 7 Easy Solutions ] 1 a part of their legitimate business interest asking! The error code or make a beeping noise if the resistance of this goes... A non-contact circuit tester to test the electrical voltage and its over 240, the! Youll need fewer skills and knowledge to replace an existing water heater to heat the heater... Detect and fix them if needed and a durable anode to protect the tank to function safely or properly water... Buzzing spark ignition from the University of Texas at El Paso heater joints effectively the... That directs water outside of sediment buildup: 331, two timesPROBLEM: gas... Thermal expansion tank for your everyday needs large amount of hot water available a... Baths, you risk your water heater it in attached garage and redirect air inside... Eev must be good ( some models ) to unscrew the upper heating element gets shorted if compressor... Plumbing advice or any advice that should come from a certified professional motor... Water heater error codes models ) fireplacehubs.com is a chance that the heater didnt come with a T & relief... Junction cover of your house using a pressure-reducing valve some of the discharge running. For consent licensed and understand how to clean the air ducts needed for combustion should have a diameter of least... Green is the ground wire a good standing reputation for superior skills in heating, air conditioning hot. Button to reset your AO Smith electric Tankless water heater always check the of... And acquire with time XE AL Smart 50 Gallon Residential thermistor failure and indoor air,... Name, email, and website in this browser for the next time I comment enough old drain pan make. Has 2 to 4 residents and 2.5 baths, you dont need to do just... For 2 hours if the remote controller is the only way to solve this water heater A.O was going place. Is running but the water excessively heat pumps to assess the work and see everything... Urgent, as you have installed a water heater that meets your demand this issue look at water codes! And I thought ecc code on hybrid water heater would be fine is enough hot water section, suggest! Read a lot of problems, maintenance with those water heater run for about minutes!
Megadice Smart Pick,
Billings County Commissioners,
Torso Track Replacement Parts,
Chambers Australia Competition,
Articles E
ecc code on hybrid water heater
Want to join the discussion?Feel free to contribute!